Printer troubleshooting technician providing live chat help

Joe B.

Reviewed for technical accuracy

Specialities: HP LaserJet & OfficeJet Pro, ADF/flatbed scanners, Firmware, Paper handling, Small-business MFP fleets

Fix HP 31.13.13 / 31.13.00 Scanner Error — ADF not feeding, paper won’t pick, multi-feed, dirty rollers, sensor faults

Technician avatar Technician
Hi! We’ll get past the HP 31.13.13 Scanner Error and the Automatic Document Feeder (ADF) not pulling paper.
A few quick details help target the fix: Which model (e.g., LaserJet Pro MFP, PageWide, OfficeJet Pro)? Does the flatbed scan still work? When you press Copy/Scan, do you hear the ADF motor spin or see a partial pull then stop? Any recent calibration or maintenance kit change?
Customer
It’s an HP LaserJet Pro M428fdw. Flatbed scans fine. With the ADF, it tries to grab the first page, then stops and throws 31.13.13 Scanner Error. This started after we ran an ADF calibration.
Technician avatar Technician
Got it. On these HP MFPs the code 31.13.13 (and siblings 31.13.00 / 31.13.11) indicates the ADF feed detect sequence failed. Typical causes are glazed pickup rollers, a worn separation pad, debris on the paper-present/exit sensors, skewed ADF hinge, or a firmware/NVRAM glitch after calibration.
Plan: 1) Inspect & clean roller set. 2) Check the two ADF sensors. 3) Reseat the ADF cable. 4) Reset the scanner subsystem and run a proper ADF calibration. 5) If needed, replace roller kit/separation pad.
Customer
Where are the rollers and sensors? I only see the input tray at the top and a small access door on the ADF.
Technician avatar Technician
Step 1 — Clean the ADF pickup system
• Open the ADF input tray. You’ll see a grey/black pickup roller at the front. Rotate it by hand and wipe with a lint-free cloth slightly dampened with isopropyl alcohol (90%+).
• Flip open the ADF top cover and the small service door above the scan glass. Clean the separation pad (the rubber strip that prevents double feed). If it’s smooth or shiny, it’s likely worn.
• Remove any adhesive, staples, or toner dust on the feed path. Even a small slip of paper can trigger the ADF won’t feed loop and the 31.13.13 error.
Customer
Cleaned. The roller looked glazed. I can hear the motor now, but it still errors out on page one. Where are those sensors?
Technician avatar Technician
Step 2 — Check ADF paper-present & exit sensors
• Inside the ADF throat, just past the pickup roller, there’s a tiny optical sensor flag. Move the flag gently and blow out dust; make sure it springs back freely.
• The second sensor sits near the ADF output/turnaround. Open the rear access or lift the ADF cover to reach it. Clear any scraps of paper.
• While you’re there, verify the ADF hinge isn’t offset and the document guides are snug to the paper size — false skew trips the error.
Customer
Sensors look fine. We also updated firmware last month. Could the calibration have messed up alignment?
Technician avatar Technician
Possibly. Let’s reset the scanner controller and re-run calibration.
Step 3 — Reset & recalibrate
1) Power off the printer. Unplug for 60 seconds. Hold the Cancel button while powering on to clear a stuck scan job (model-dependent).
2) In Service or Setup → Tools, run Scanner/ADF calibration. Use 10–20 clean sheets of Letter/A4 75–90 gsm. Set the guides tight, try one-sided first, then duplex.
3) In Paper Settings, set correct paper size and type; mismatch can cause ADF not feeding and multi-feed detection faults.
Customer
After the reset it pulled one sheet, then jammed. The pad looks worn. Do I need parts?
Technician avatar Technician
Likely, yes. Step 4 — Replace ADF roller kit & separation pad
• HP sells ADF Maintenance Kit (pickup roller + separation pad) for M428-series. Swapping both usually clears 31.13.13 and ADF won’t feed loops.
• While open, reseat the flat ADF ribbon cable to the scanner board and inspect the small ADF clutch if present — a slipping clutch causes partial pulls.
• After replacement, update to the latest firmware and repeat the calibration sequence.
Customer
We also scan mixed sizes and sometimes receipts. Could that trigger the error?
Technician avatar Technician
It can. For best results:
• Keep stacks flat, fan-separated, and remove curled or glossy sheets that slip.
• Don’t mix receipts with full-size pages in one pass; use the flatbed or batch by size.
• Disable multi-feed detection only for problem batches, then re-enable. Incorrect settings can mimic a sensor failure and throw 31.13.x errors.
Customer
If replacing rollers doesn’t help, is there a deeper repair?
Technician avatar Technician
Advanced options:
• Inspect/replace the ADF drive assembly (gears/clutch) and the scanner PCA if the sensor never toggles.
• Run a partial NVRAM reset (service-menu) to clear corrupt ADF parameters.
• For models like LaserJet M479/M428/OfficeJet Pro 902x, HP diagnostics have an ADF component test that cycles motors and reads sensors live.
Customer
After cleaning the rollers and pad, recalibrating, and tightening the guides, it feeds normally — no more 31.13.13. Thanks!
Technician avatar Technician
Summary: To fix HP 31.13.13 Scanner Error — ADF won’t feed, clean or replace the pickup rollers and separation pad, clear and test the ADF sensors, reseat cables, reset the scanner, update firmware, and rerun ADF calibration. Need hands-on help or part numbers? Open the chat.

Quick answer: the accepted fix

Accepted fix for HP 31.13.13 Scanner Error (ADF): clean/replace the ADF pickup roller and separation pad, dust the paper-present/exit sensors, reseat cables, power-cycle and run ADF calibration, then update firmware. If errors persist, install the ADF roller kit or service the clutch/drive.


What causes HP 31.13.13 Scanner Error (ADF won’t feed)?

The code appears when the ADF feed sequence doesn’t meet timing: the pickup roller doesn’t move paper to the paper-present sensor, the exit sensor never toggles, or the controller flags a multi-feed. Common reasons include glazed rollers, a worn separation pad, debris on optical sensors, loose ADF guides/hinge, or corrupted calibration/NVRAM settings after updates.

How to verify the repair worked

Load 10 sheets of plain Letter/A4. Run a Copy from the ADF, then a duplex scan. Check that pages feed smoothly, no skew, and the printer doesn’t log 31.13.00/31.13.13. If it slips, replace the roller kit/separation pad and ensure the paper type/size matches tray settings.

HP ADF won’t feed — quick tips

Most 31.13.x errors come from traction loss or blocked sensors.

Quick path: clean rollers → clean separation pad → dust the sensors → power-cycle & ADF calibration → verify paper settings → update firmware → replace ADF roller kit if still failing.

Disclaimer: This information is AI-generated and intended for general guidance only. For advice specific to your environment, please consult a verified expert on Whizz-Tech before making decisions.


Getting Started Is Easy

Ask for help, 24/7

Members enjoy round-the-clock access to 12,000+ verified Experts, including tech support, mechanics, vets, and more.

Expert will respond in minutes

We match you with an Expert who specializes in your situation. Talk, text, or chat — whichever you prefer.

Save time & money

No scheduling hassles or expensive consults. Membership can save you significant time and money each month.

FAQ

What does HP error 31.13.13 (or 31.13.00) mean?

It’s an ADF feed fault: the scanner controller didn’t see paper reach the sensor on time. Causes include dirty pickup rollers, worn separation pad, blocked ADF sensors, or firmware/calibration issues.

How do I fix an ADF that won’t feed?

Clean/replace the ADF roller kit and separation pad, dust sensors, set correct paper size/type, run a scanner/ADF calibration, and update firmware. Replace the clutch/drive if slippage persists.

Can mixed paper sizes cause 31.13.13?

Yes. Curled, glossy, or mixed-size stacks can slip or skew and trigger multi-feed. Batch by size or use the flatbed for receipts.

What parts are commonly replaced?

The ADF pickup roller, separation pad, sometimes the ADF clutch or sensor flag. Most HP MFPs have an inexpensive ADF Maintenance Kit.

Common HP 31.13.13 ADF problems and quick fixes
SymptomLikely causeQuick fix
31.13.13 Scanner Error Dirty roller / worn separation pad Clean or replace ADF roller kit
ADF won’t pull page Blocked paper-present sensor Clean sensor flags; remove scraps
Pulls 1 sheet then stops Slip in ADF clutch/drive Inspect clutch, reseat cable, update firmware
Skewed, multi-feed Loose guides, mixed sizes Tighten guides, batch by size, recalibrate

Step-by-step (HP MFP ADF)

  1. Power off, unplug 60s; clear stuck scan jobs.
  2. Clean ADF pickup rollers and separation pad; remove debris.
  3. Dust paper-present and exit sensors; verify flag movement.
  4. Rerun ADF calibration; set correct paper size/type; update firmware.
  5. Replace ADF roller kit; inspect clutch/drive if slipping continues.

Note for mixed environments (macOS/Windows)

  1. Driver settings like “Detect original size” and duplex defaults affect feed timing. Align settings with media loaded.
  2. If the ADF is unreliable for receipts, use the flatbed or a sheet-fed scanner to avoid recurring 31.13.x codes.

Sources

Matt Verified Icon
Matt ● replies in < 1 min
Technician Expert
⭐⭐⭐⭐⭐ Trusted by 27,000+ customers
Avatar
Alex · Expert's Assistant